24-HOUR EVLP REFERRAL LINE

1-844-367-3857

For any other inquiries, please reach us via Contact Us tab.

24-HOUR EVLP REFERRAL LINE
1-844-367-3857

For any other inquiries, please reach us via Contact Us tab.

Terms of Use

TERMS OF USER AGREEMENT

This website may contain information about United Therapeutics Corporation, its subsidiaries and affiliates (collectively, “Company”), and/or one or more product marketed by Company. Access to and use of this website is subject to the following terms and conditions and all applicable laws. By accessing and using the website, you agree to be bound by and to comply with this Terms of Use Agreement without limitation or qualification and you acknowledge that it supersedes any other agreement between you and Company regarding this subject matter. If you do not agree with these Terms of Use, please exit and do not use the website. These terms of use may be revised by Company from time to time and you should therefore review them on your next visit to the website. Your continued use of the website following any such posting will be deemed as consent to the new notice, term or condition.

a) You may browse this website. You may download and print material from this website, provided that you retain all copyright and trademark notices contained in such materials. You may use such downloaded and printed materials for your own personal, non-commercial use. You may not use in any manner such materials for public or commercial purposes without Company’s express written consent.

b) All product names, logos and service marks displayed on this website that are identified by “™” or “®” or that appear in type form different from that of the surrounding text are trademarks owned by or licensed to Company or our affiliates (collectively, “Trademarks”), unless otherwise identified as being owned by another entity. Nothing contained herein shall be construed as conferring by implication, estoppel or otherwise any license or right, either express or implied, under any patent or Trademark of Company or any third party. No use of any Trademark may be made without the prior written authorization of Company, except to identify the product or services of the company.

c) Company’s products are available only by prescription from licensed health care professionals. Company does not provide medical advice or services.

d) You should assume that all content of the website is protected by copyright law unless otherwise noted and may not be used except as provided herein, or with the express written permission of Company. Except as expressly provided above, nothing contained herein shall be construed as conferring any license or right under any Company copyright.

e) You are prohibited from posting or transmitting to the website any unlawful, threatening, libelous, defamatory, obscene, inflammatory, pornographic or profane material or any material that could constitute or encourage conduct that would be considered a criminal offense, give rise to civil liability or would otherwise violate the law. Company will fully cooperate with any law enforcement authorities or court order requesting or directing Company to disclose the identity of anyone posting any such information or materials.

TERMS OF USER AGREEMENT

COMPANY MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND OR NATURE WITH RESPECT TO ANY OF THE INFORMATION CONTAINED ON THIS WEBSITE. COMPANY DISCLAIMS ALL REPRESENTATIONS AND/OR WARRANTIES, EXPRESS OR IMPLIED, CREATED BY LAW, CONTRACT OR OTHERWISE, INCLUDING WITHOUT LIMITATION, ANY WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, TITLE OR NONINFRINGEMENT.

In no event shall Company be liable for any damages of any kind or nature, including without limitation, direct, indirect, special, consequential or incidental damages arising from or in connection with the existence or use of the website and/or the information.

IMPORTANT SAFETY INFORMATION FOR XVIVO PERFUSION SYSTEM (XPS™) WITH STEEN SOLUTION™ PERFUSATE - P180014

Warnings and Precautions

General Warnings

The safety and effectiveness of the XPS™ System with Steen Solution™ perfusate device were not evaluated with ideal criteria donor lungs.

Risk for Contamination and Mechanical Trauma

The degree of organ manipulation required for airway and vascular cannulation carries the potential for contamination and mechanical trauma of the donor lungs. Even though not contraindicated, it is not recommended to use an organ with evident signs of mechanical trauma or major contamination.

XPSTM Machine Operation-Related Warnings

See Warnings and Precautions in the XPSTM System Instructions for Use manual.

STEEN SolutionTM Warnings

The responsibility to adhere to the approved labeling and Instructions for Use rests with the user. The Instructions for Use are only provided as suggestions for procedure. The user must, on the basis of his or her medical training and experience, evaluate the suitability of this procedure. When administered systemically, human serum albumin and Dextran have been associated with rare allergic reactions. However, no such reactions have been reported with either of these substances when used for ex vivo lung preservation.

XVIVO Lung Cannula SetTM Precautions

Store at room temperature. Use only undamaged/unopened containers. Single Use Only.

XVIVO Organ ChamberTM Precautions

Store at room temperature. Use only undamaged/unopened containers. Single Use Only.

XVIVO Disposable Lung CircuitTM Precautions

Store at room temperature. Use only undamaged/unopened containers. Single Use Only.

XVIVO Disposable Lung KitTM Precautions

Store at room temperature. Use only undamaged/unopened containers. Single Use Only.

XPSTM Machine Operation-Related Precautions

See Warnings and Precautions in the XPSTM System Instructions for Use manual.

STEEN SolutionTM Precautions

STEEN SolutionTM is intended for single use only and MAY NOT BE REUSED. Any leftover solution must be disposed of after the procedure.

Do not use STEEN SolutionTM if the solution is not clear, the bottle is damaged, the flip-tear seal has been tampered with, or if the “use by” date has expired. Transplant Suitability Post-Ex Vivo Lung Perfusion (EVLP) The responsibility for correct clinical use and interpretation of the lung function evaluations during EVLP in determining transplant suitability resides exclusively with the transplant surgeon.

Like in any other clinical decision, all available data should be taken into consideration when determining the suitability of an organ for transplantation; that is, the transplant surgeon is clinically satisfied with the lung evaluation. This criterion should take priority, since the transplant surgeon is the ultimate responsible person for safely transplanting EVLP lungs. The use of the EVLP lung physiologic evaluations in determining transplantability (e.g., EVLP transplantability criteria) has been evaluated in the clinical studies, including the NOVEL trial (see summary of NOVEL study below). Validation has not occurred as to whether the parameters are adequate as surrogates for in vivo performance.

The use of ex-vivo perfusion/ventilation discrete parameters on their own to determine transplant suitability according to the two sets of transplantability criteria used in the NOVEL and NOVEL EXTENSION respectively have not been validated. Clinicians should exercise discretion when using these criteria as the main decision-making tool for transplantability and instead utilize the perfusion/ventilation trends coupled with EVLP x-rays and bronchoscopies and their clinical expertise to make decisions on transplant suitability. Two different transplant suitability criteria (NOVEL: 2 consecutive delta PaO2s ≥ 350 vs NOVEL Extension: 2 non-consecutive delta PaO2s ≥ 350 OR 1 absolute PaO2 > 400) have been used in the NOVEL and NOVEL EXTENSION respectively, and neither of these criteria have been validated. The transplant suitability criteria between the NOVEL and NOVEL Extension studies have shown no difference in survival and/or incidence of Primary Graft Dysfunction (PGD).

Potential Adverse Events

The XPSTM with STEEN SolutionTM Perfusate device is indicated for use only on previously unacceptable excised donor lungs in an ex vivo setting. There is no direct patient contact when this device is used as labeled; however, the device has a direct contact with the lungs that are subsequently transplanted into the recipients. The donor lung quality and optimization after preservation have direct effects on allograft function and survival.

The potential for contamination and mechanical trauma, due to the manipulation and cannulation of the lung airway and vascular structures, may lead to complications after transplantation.

Patients receiving a lung treated with the XPSTM System with STEEN SolutionTM Perfusate device may experience adverse events including those experienced with any lung transplant.

Below is a list of the potential adverse effects associated with the use of the device.

  • Death
  • Renal failure or dysfunction
  • Respiratory dysfunction or failure
  • Respiratory infection
  • Sepsis
  • Primary graft dysfunction
  • Acute or chronic rejection
  • Cardiac arrhythmias
  • Bronchiolitis Obliterans Syndrome (BOS)
  • Bronchial stenosis/Dehiscence
  • Post-operative bleeding/hemorrhage
  • Hemothorax
  • Pneumothorax
  • Re-transplantation

Indication

Indicated for use in flushing and temporary continuous normothermic machine perfusion of initially unacceptable excised donor lungs during which time the ex-vivo function of the lungs can be reassessed for transplantation.

Prescription Information

Caution: Federal law (USA) restricts this device to sale by or on the order of a physician. See the Physician Labeling for further detailed information. For further information, please call (303) 395-9171 and/or consult XVIVO’s website at www.xvivoperfusion.com.